2 Years’ Warranty for ASTM A194 2H Heavy Hex Nuts to Tunisia Manufacturer

2 Years’ Warranty for ASTM A194 2H Heavy Hex Nuts to Tunisia Manufacturer

Short Description:

ASTM A194/A194M 2H Heavy Hex Nuts API 6A 6D Flange Valve Wellhead ASME/ANSI Flange Heavy Hex Nuts Dimension Standard: ASME B18.2.2, ASME B18.2.4.6M, ISO 4033, Din934 H=D Inch Size: 1/4”-4” with various lengths Metric Size: M6-M100 with various lengths Other Available Grade: ASTM A194/A194M 2H, 2HM, 4, 4L, 7, 7L, 7M, 8, 8M, 16 and so on. Finish: Plain, Black Oxide, Zinc Plated, Zinc Nickel Plated, Cadmium Plated, PTFE etc. Packing: Bulk about 25 kgs each carton, 36 cartons each pallet Advantag...


Product Detail

Product Tags

We retain bettering and perfecting our goods and service. At the same time, we perform actively to do research and enhancement for Steel Tower Bolts price, Din127B Lock Washer price, China Stud Bolt, We will provide high-quality products and excellent services at competitive prices. Start benefiting from our comprehensive services by contacting us today.
2 Years’ Warranty for ASTM A194 2H Heavy Hex Nuts to Tunisia Manufacturer Detail:

ASTM A194/A194M 2H Heavy Hex Nuts

API 6A 6D Flange Valve Wellhead ASME/ANSI Flange Heavy Hex Nuts

Dimension Standard: ASME B18.2.2, ASME B18.2.4.6M, ISO 4033, Din934 H=D

Inch Size: 1/4”-4” with various lengths

Metric Size: M6-M100 with various lengths

Other Available Grade:

ASTM A194/A194M 2H, 2HM, 4, 4L, 7, 7L, 7M, 8, 8M, 16 and so on.

Finish: Plain, Black Oxide, Zinc Plated, Zinc Nickel Plated, Cadmium Plated, PTFE etc.

Packing: Bulk about 25 kgs each carton, 36 cartons each pallet

Advantage: High Quality, Competitive Price, Timely Delivery,Technical Support, Supply Test Reports

Please feel free to contact us for more details.


Product detail pictures:

2 Years’ Warranty for ASTM A194 2H Heavy Hex Nuts to Tunisia Manufacturer detail pictures


To constantly improve the management system by virtue of the rule of sincerely, good faith and quality are the base of enterprise development, we widely absorb the essence of related products internationally, and constantly develop new products to meet the demands of customers for 2 Years’ Warranty for ASTM A194 2H Heavy Hex Nuts to Tunisia Manufacturer, The product will supply to all over the world, such as: Algeria, Finland, Cairo, Immediate and expert after-sale service supplied by our consultant group has happy our buyers. Comprehensive Info and parameters from the merchandise will probably be sent to you for any comprehensive acknowledge. Free samples may be delivered and company check out to our corporation. n Morocco for negotiation is constantly welcome. Hope to get inquiries type you and construct a long-term co-operation partnership.



  • Departmental Procedures & Guidelines for Inspections, Certifications, Load Testing, Repairs & Painting of Fire Escapes
    Inspections by Structural Engineers, Fire Escape Engineers or others acceptable to the Official:
    In layman’s terms, the city official is looking for a registered structural engineer or others qualified and acceptable by the Fire/Code Official to do a Critical Examination in lieu of a Live Load Test (criteria submitted or discussed prior to inspection) and issues written verification and certification that all connections are free of internal rust or rot as well as all original hardware (square head bolts or rivet) are reinforced and or replaced in lieu of Live Load Test. All supports (thru-bolts or cemented) into the wall must be verified and certified in lieu of Live Load Test. A fire escape confidence test and tag must be submitted if fire escape passed. The report with photos identifying violations for repairs must include repair criteria submitted to the official for repair vendor to use as a guide during and with engineer oversight of permitted repairs. A Fire Escape Confidence Test and tags identifying certified condition are then submitted. Recommended cycle for live load testing is 20 yrs after total refurbishment or as required by official.

    Repairs by Ornamental Ironworkers, Welding Companies or others acceptable to the Official:

    In layman’s terms, the city official is looking for a qualified licensed repair vendor to do all work under repair permit (if required) with engineer oversight of repair criteria submitted for approval to the official in lieu of Live Load Test. All connections must be free of internal rust or rot, spot primed and sealed. All worn material repaired and or replaced. All supports into wall reinforced, repaired and certified in a Fire Escape Confidence Test. In lieu of Live Load Test, all square head bolts, rivets and or welded connections must be certified, reinforced and or replaced based on age or condition. All ladders and cantilevers must be balanced and drop 2-3 ft per second, hit the ground and stay down and must lead to a public way. All roof ladders must be secure. No full painting of any fire escape until all spot painted repairs are inspected and certified under engineer oversight and or city official permit sign-off. Full replacement is subject to permits and or possible code upgrade requirements.
    Painting by EPA Licensed Renovators (if lead paint is present) or others acceptable to Official:
    In layman’s terms, the city official is looking for a paint vendor (EPA Certified Renovator if required) to do all work as per EPA Guidelines due to the fact that all fire escapes older than 1978 are presumed to have lead (EPA) unless identified as no lead or low lead by a licensed lead inspector. Entire building will be notified with signage and all precautions shall be taken to collect paint chips at grade. No sandblasting or power assisted scraping without full fire escape encapsulation under EPA Guidelines. All major connection shall be sealed from water intrusion before during or after painting. All escapes should be spot painted every 3-5 yrs and fully painted every 5-10 yrs or as needed or ordered by a Fire/Code Official.
    Fire Escape Codes:
    MASS BUILDING CODE 1001.3 TESTING AND CERTIFICATION ALL EXTERIOR BRIDGES, STEEL OR WOODEN STAIRWAYS, FIRE ESCAPES AND EGRESS BALCONIES SHALL BE EXAMINED AND OR TESTED, AND CERTIFIED FOR STRUCTURAL ADEQUACY AND SAFETY EVERY FIVE YEARS, BY A MASS REGISTERED PROFESSIONAL ENGINEER, OR OTHER QUALIFIED AND ACCEPTABLE TO THE BUILDING OFFICIAL, WHO SHALL THEN SUBMIT AN AFFIDAVIT TO THE BUILDING OFFICIAL.

    NFPA Lifesafety Code 101 7.2.8.6.2 The authority having jurisdiction shall be permitted to approve any existing fire escape Stair that has been shown by load test or other satisfactory evidence to have adequate strength.
    For more information please visit our website at https://fireescapeengineers.com or call 866-649-0333
    #3006

    Related Products